Odme S-3000 Manual

We are service provider offering yearly and 5 yearly ODME calibration and repair services for KSB Seil Co. Ltd Korea equipment’s at Ports of Singapore, India. Our group company is authorized by Maker KSB Seil and technicians are maker approved / certified to carry our all ODME calibration and repair services.We supply spare parts Original and Genuine from Ex-stocks Singapore. Large stocks of KSB Seil Co., Ltd Korea spares and upgrade equipment’s are available for immediate shipping from our Singapore Workshop.
Attending technicians are trained and certified by the manufacturer and carry out adequate equipment’s and ready stock spares to ensure smooth and in time completion of works, ensuring trouble free operation of the equipment. We ensure 100% successful Repair Services.
KSB Seil-Seres ODME (S-3000, SS-2000)
Oil Discharge Monitoring equipment (ODME)
Attending engineers are trained and hold valid Certificates by ODME maker KSB Seil Co (ex Seil Seres) for ODME SS-2000, ODME S-3000 Ver1 and ODME S-3000 Ver2 (Biofuel).
After on board inspections / Servicing / Calibrations, KSB Seil Test Certificates are issued as per ship owner’s requirements
Our Service Engineers are available 24×7 for remote assistance to ship staffs in order to solve any reported functional challenge.
ODME Annual Inspection/Calibration and Certification by the maker, using dedicated portable Diagnostic-Calibration unit.
Upgrade Package of the ODME models MKII, MKIII, SS-2000 and S-3000 Ver1 to ODME S-3000 Ver2.
KSB Seil try the best to provide the high quality products and serivces. All these international certificate which approved by authorized authentication institutions, prove that KSB Seil’s hard work to meet our customers expectation.

R&S®FSV3-K145 NR 5G Uplink Measurements User Manual Describes the specific functions of the application, including the remote control commands with programming examples.For information on operating the R&S®FSV3000 and R&S®FSVA3000 see the user manual of the base unit.The online version contains the documentation for the R&S®FSV3000 and R&S®FSVA3000 base unit and ALL options for immediate. ODME Seil Seres S-3000. This equipment is in full compliance with the current IMO/MARPOL Regulations MEPC 108(49) for Tank. $0.00 Ex Tax: $0.00.

Odme S-3000 Manual The global certifications cover:

Odme S-3000 Manual Pdf

Odme S-3000 Manual
  • Valve Remote Control System
  • Hydraulic Actuator
  • Oil Discharge Monitoring Equipment
  • Services
KSB Service supports customers from all fields of application, whether it is industrial or municipal plant and power station operators. Our service network, with more than 2,600 specialists at over 140 service centres worldwide, is the perfect basis for first-class pump and system maintenance services.
  • Pump, valve and rotating equipment services are the basis of our flexible service concepts for products by KSB and other manufacturers.
  • KSB services provided on-site and at the service centers through customized service solutions for the entire life cycle
  • Certified service specialists for high-quality and competent consultancy and assistance
  • Comprehensive system analyses increase pump system efficiency
  • Bespoke service concepts help optimize system availability
  • Original KSB spare parts help avoid costly downtime

ODME(Oil Discharge Monitoring Equipment) is an equipment for observing and deciding to discharge the cargos according to the rules when each tanker hull is cleaned with sea water after discharging cargos reloading another cargos. They are discharged again after being stored in the slop tank.

ODME S-3000 Main Components:
  • Controller
  • Oil Content Meter
  • Motro Starter
  • Pressure Switch
  • Motor/Pum[ Assy.
  • PPM Measurer
  • Hydraulic Panel
  • Sampling & Flowmeter Probe
ODME S-3000 applies with IMO Resolution A.586 (XIV), MEPC.108(49) and MED 96/98 EC to be fitted on board of new tanker, and obtain type approvals from classifications.

KSB Seil Seres S-3000 is required by MARPOL regulations and it’s a system for controlling the discharge into the sea of the oily products in ballast from the cargo spaces of tankers. This equipment is in full compliance with the current IMO/MARPOL Regulations MEPC 108(49) for Tanker Ships.

Odme S-3000 Operation Manual

ODME S-3000 Main Components:S-3000
  • Display of Ships Position GPS
  • Self-calibration with automatic zeroing.
  • Self-Cleaning of Measuring Vessel.
  • Across running to check all components.
  • Back flushing.
  • PPM Alarm.
  • Total Oil Limit Alarm.
  • Automatic Selection of Sample Monitoring
The KSB Seil Seres S-3000 version 2 is the upgrade version with the Bio fuel blends revision.

Odme S-3000 Ver.2 Manual

The System is approved in accordance with Resolution A 586 (XIV) and MEPC 51 (32) for Oily Products and also for oily substances. This equipment is in full compliance with IMO RES A 586(XIV) – MEPC 51 (32) for Tanker Ships. The SEIL SERES S663 MK-III is suitable to be retrofitted to all Tanker Ships build before the year 2005. ODME S 663 MK III is required by MARPOL regulations and it’s a system for controlling the discharge into the sea of the oily products in ballast from the cargo spaces of tankers. The core is the Oil Content Meter, which uses an intrinsically safe multi cell detection system with automatic compensation, for detecting the actual PPM value of oil content.

It consists of the following parts:
  • Controller
  • Oil content meter.
  • DP Transmitter.
  • Hydraulic panel.
  • Motor sampling pump

Odme Seil Seres S-3000 Manual

S-3000

Odme S-3000 Manual Pdf

The SEIL SERES S663 MK-III can be upgraded to the latest ODME systems from KSB Seil Seres like the S-3000 Version 2.

The Seil Seres SS-2000 is suitable to be retrofitted to all Tanker Ships build before the year 2005. ODME SS-2000 is required by MARPOL regulations and it’s a system for controlling the discharge into the sea of the oily products in ballast from the cargo spaces of tankers. The System is approved in accordance with Resolution A 586 (XIV) and MEPC 51 (32) for Oily Products. Exists different alternatives to upgrade this system to S-3000 or S-3000 version 2.

Features:
  • Self-calibration and automatic zeroing.
  • Self-Cleaning of Measuring Vessel.
  • Across running.
  • PPM Alarm.
  • Fresh water flushing and back flushing.
  • Total Oil Limit Alarm.
  • Automatic Selection of Sample Monitoring.
  • Up to 3 channels etc.